{"product_id":"labconco-3-ft-protector-airo-benchtop-filtered-fume-hood-37-7-in-115v-230v-50-60hz-10-or-5-amp","title":"Labconco 3 ft. Protector Airo Benchtop Filtered Fume Hood, 37.7 In., 115V\/230V, 50\/60Hz, 10 or 5 Amp","description":"\u003ch2\u003eLabconco 3 ft. Protector Airo Benchtop Filtered Fume Hood, 37.7\" , 115V\/230V, 50\/60Hz, 10 or 5 Amp, with 2 Service Fixtures-1 GFCI Duplex Options\u003c\/h2\u003e\n\u003cp\u003eThe Protector Airo Filtered Fume Hood requires no ducting and is available in 3' and 4' widths and 31.7\" and 37.7\" depths. Neutrodine® Unisorb Filtration Technology offers comprehensive molecular filtration. eGuard® communication software offers real-time monitoring on the user’s phone or computer. From a remote location, data such as usage authorization, filter saturation detection, sash position and temperature may be observed and managed.\u003c\/p\u003e\n\u003cp\u003eErlab-proven Neutrodine® Unisorb Filters are the heart of GFH Filtration Technology.\u003c\/p\u003e\n\u003cp\u003eBenchtop models include a fiberglass panelized liner. Models are available for carbon-only, carbon with acid sensor, carbon with formaldehyde sensor, or HEPA-only filtration. Filters are sold separately. To determine if your application is right for a Protector Airo, please request a Chemical Assessment from a Labconco specialist who can recommend the appropriate enclosure and filters for your application.\u003c\/p\u003e\n\u003ch3\u003eFeatures (All Models)\u003c\/h3\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eEco-Foil™ air foil with aerodynamic Clean-Sweep™ airflow openings\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eCord-Keeper™ Slots on left and right side of air foil\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRemovable front and side panels, and front and interior service access panels for access to plumbing and electrical wiring\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eBy-pass airflow design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eGlacier white powder-coated steel exterior\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eChemical-resistant, fiberglass-reinforced, composite panel liner\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePre-wired vapor-proof LED lights for up to 63 foot candles rated for 50,000 hours\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eeGuard2 software communication\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFactory-installed command module, fan button and light button\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRoughing prefilter\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eBuilt-in exhaust fans to maintain 60 fpm face velocity at 16\" sash opening height\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSound pressure of \u0026lt;60 dB(A) with sash at operating height and \u0026lt;48 dB(A) with sash closed\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eAudible\/visual alarms for breakthrough detection, temperature ≥40° C (104° F), fan failure and high sash position opening. At ≥60° C (140° F), all fans stop\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eSingle piece, tempered safety glass vertical-rising sash with cable pulley, sash weight and powder-coated aluminum sash handle and tracks with airflow openings. Sash stop at 16\" sash opening height on 4’ models and 13” sash opening height on 3’ models. Sash opens to 26\" high for loading\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFactory-prepared for up to two electrical duplex receptacles and four service fixtures\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003e28.5\" high sightline from the work surface and header panel\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l3 level1 lfo1; tab-stops: list 36.0pt;\"\u003ePower cord with plug\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003cb\u003eFixtured Models May Feature\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eTwo pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l1 level1 lfo2; tab-stops: list 36.0pt;\"\u003eOne pre-wired GFCI electrical duplex receptacle on lower right side\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003cb\u003eRequired Accessories (Not Included)\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\"\u003eNeutrodine® Unisorb Filters (except HEPA only models which require HEPA filters). Number of filters required is determined by the width of the hood\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\"\u003eWork Surface\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l2 level1 lfo3; tab-stops: list 36.0pt;\"\u003eBase Cabinet or Stand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003cb\u003eOptions Available Include\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003eHEPA filter\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003eRegion-specific electrical plug configurations\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo4; tab-stops: list 36.0pt;\"\u003eService fixtures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003cb\u003eCompliance\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSEFA 9, DHIII\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo5; tab-stops: list 36.0pt;\"\u003eSEFA 8, Cabinet Surface Finish Tests\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo5; tab-stops: list 36.0pt;\"\u003eModified ASHRAE 110\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo5; tab-stops: list 36.0pt;\"\u003eANSI Z9.5-2011\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo5; tab-stops: list 36.0pt;\"\u003eAFNOR NF-X 15-211\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo5; tab-stops: list 36.0pt;\"\u003eASTM E84-09C\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo5; tab-stops: list 36.0pt;\"\u003eUL Standard 61010-1\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l4 level1 lfo5; tab-stops: list 36.0pt;\"\u003eCAN\/CSA C22.2 No. 61010-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eModels available:\n\u003cul\u003e\n\u003cli\u003e3 ft Width:\n\u003cul\u003e\n\u003cli\u003eInterior Depth: 25.3”\u003c\/li\u003e\n\u003cli\u003eExterior Depth: 31.7”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e3 ft Width:\n\u003cul\u003e\n\u003cli\u003eInterior Depth: 31.3”\u003c\/li\u003e\n\u003cli\u003eExterior Depth: 37.7”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e4 ft Width:\n\u003cul\u003e\n\u003cli\u003eInterior Depth: 31.3”\u003c\/li\u003e\n\u003cli\u003eExterior Depth: 37.7”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensor Packages available:\n\u003cul\u003e\n\u003cli\u003eSolvent sensor\u003c\/li\u003e\n\u003cli\u003eSolvent sensor + acid sensor\u003c\/li\u003e\n\u003cli\u003eSolvent sensor + formaldehyde sensor\u003c\/li\u003e\n\u003cli\u003eHEPA Filter only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll models require (not included):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNeutrodine® Unisorb filters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"542\" style=\"border-collapse: collapse; width: 407pt;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"165\" style=\"mso-width-source: userset; mso-width-alt: 5280; width: 124pt;\"\u003e \u003ccol width=\"377\" style=\"mso-width-source: userset; mso-width-alt: 12064; width: 283pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"17\" style=\"height: 12.75pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl70\" width=\"165\" style=\"height: 12.75pt; width: 124pt;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl70\" width=\"377\" style=\"width: 283pt;\"\u003e\n\u003cdiv style=\"box-sizing: inherit; margin-inline-start: auto; font-size: 0.9375rem;\"\u003e485.0\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.75pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl70\" style=\"height: 12.75pt;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"xl70\"\u003e\n\u003cdiv style=\"box-sizing: inherit; margin-inline-start: auto; font-size: 0.9375rem;\"\u003e36\" w x 37.7\" d x 54.2\" h\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.75pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl70\" style=\"height: 12.75pt;\"\u003eElectrical\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e115V, 50\/60 Hz, 10A \/\u003cspan style=\"mso-spacerun: yes;\"\u003e   \u003c\/span\u003e230V, 50\/60Hz, 5 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.75pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl70\" style=\"height: 12.75pt;\"\u003eMetric Dimensions\u003c\/td\u003e\n\u003ctd class=\"xl70\"\u003e\n\u003cdiv style=\"box-sizing: inherit; margin-inline-start: auto; font-size: 0.9375rem;\"\u003e91.4 x 95.8 x 137.7 cm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.75pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl70\" style=\"height: 12.75pt;\"\u003eMetric Weight (kg)\u003c\/td\u003e\n\u003ctd class=\"xl70\"\u003e\n\u003cdiv style=\"box-sizing: inherit; margin-inline-start: auto; font-size: 0.9375rem;\"\u003e220.0\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.75pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl70\" style=\"height: 12.75pt;\"\u003eAir Foil Type\u003c\/td\u003e\n\u003ctd class=\"xl70\"\u003eEco-foil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"17\" style=\"height: 12.75pt;\"\u003e\n\u003ctd height=\"17\" class=\"xl70\" style=\"height: 12.75pt;\"\u003eAirflow Type\u003c\/td\u003e\n\u003ctd class=\"xl70\"\u003eBypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Labconco","offers":[{"title":"115V 50\/60Hz 10A North America Plug \/ with 2 Service Fixtures \/ None","offer_id":53647980298578,"sku":"184310201","price":22430.0,"currency_code":"USD","in_stock":true},{"title":"115V 50\/60Hz 10A North America Plug \/ with 2 Service Fixtures \/ 1","offer_id":53647980331346,"sku":"184310202","price":22575.0,"currency_code":"USD","in_stock":true},{"title":"115V 50\/60Hz 10A North America Plug \/ No Service Fixtures \/ None","offer_id":53647980364114,"sku":"184310200","price":21425.0,"currency_code":"USD","in_stock":true},{"title":"115V 50\/60Hz 10A North America Plug \/ No Service Fixtures \/ 1","offer_id":53647980396882,"sku":"184310203","price":21550.0,"currency_code":"USD","in_stock":true},{"title":"230V 50\/60Hz 5A North America Plug \/ with 2 Service Fixtures \/ None","offer_id":53647980429650,"sku":"184310221","price":22430.0,"currency_code":"USD","in_stock":true},{"title":"230V 50\/60Hz 5A North America Plug \/ No Service Fixtures \/ None","offer_id":53647980462418,"sku":"184310220","price":21425.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0936\/5651\/4898\/files\/Labconco_4_ft._Protector_Airo_Benchtop_Filtered_Fume_Hood_37.7_In._115V_230V_50_60Hz_10_or_5_Amp.webp?v=1780609489","url":"https:\/\/medidepot.com\/products\/labconco-3-ft-protector-airo-benchtop-filtered-fume-hood-37-7-in-115v-230v-50-60hz-10-or-5-amp","provider":"MediDepot","version":"1.0","type":"link"}