{"product_id":"usa-lab-usa-ug20-high-speed-centrifuge","title":"USA Lab Table Top High Speed Centrifuge, 21000rpm (Multiple Rotor Options), 110V Precision Control","description":"\u003ch2\u003eUSA Lab Table Top High Speed Centrifuge, 21000rpm (Multiple Rotor Options), 110V Precision Control, A\u003cspan\u003eutomatic Electric Lid Lock, Stainless-Steel Chamber\u003c\/span\u003e \u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe USA Lab USA-UG20 Table Top High Speed Centrifuge is built for laboratories that demand precision, safety, and reliable high-speed centrifugation. Its brushless frequency motor delivers high torque with fast acceleration and deceleration while remaining maintenance-free and free from carbon powder pollution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe microprocessor-controlled system and digital LCD display provide clear readouts of time, speed, and relative centrifugal force (RCF), supporting accurate and repeatable centrifugation runs. With 9 programmable settings and 10 selectable acceleration and deceleration profiles, operators can tailor runs to specific laboratory requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe USA-UG20 features an automatic electric lid lock, overspeed and overtemperature protection, and imbalance detection. Its all-steel body, stainless-steel chamber, and three-tier safety protection system provide durable construction for demanding laboratory environments. A specialized taper sleeve connection allows quick, simple, direction-free rotor installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-path-to-node=\"0,0,0\"\u003e\n\u003cb data-path-to-node=\"0,0,0\" data-index-in-node=\"0\"\u003eMaximum Operating Speed:\u003c\/b\u003e Reaches up to 21,000 RPM for rapid phase separation and high-speed laboratory applications.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,1,0\"\u003e\n\u003cb data-path-to-node=\"0,1,0\" data-index-in-node=\"0\"\u003eHigh Relative Centrifugal Force (RCF):\u003c\/b\u003e Generates a maximum relative centrifugal force of up to ~34,400 × g for efficient pelleting of micro-particles, cellular components, and nucleic acids.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,2,0\"\u003e\n\u003cb data-path-to-node=\"0,2,0\" data-index-in-node=\"0\"\u003eMaintenance-Free Drive System:\u003c\/b\u003e Driven by a high-torque, brushless frequency induction motor that eliminates carbon dust pollution and ensures long-term maintenance-free performance.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,3,0\"\u003e\n\u003cb data-path-to-node=\"0,3,0\" data-index-in-node=\"0\"\u003ePrecision Digital Control \u0026amp; Interface:\u003c\/b\u003e Features a clear LED\/LCD digital display for real-time monitoring and adjustment of speed (RPM), g-force (RCF), time, and system alerts.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,4,0\"\u003e\n\u003cb data-path-to-node=\"0,4,0\" data-index-in-node=\"0\"\u003eDual Speed\/RCF Display \u0026amp; Toggle:\u003c\/b\u003e Allows single-touch switching between RPM and RCF calculation values without stopping the cycle.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,5,0\"\u003e\n\u003cb data-path-to-node=\"0,5,0\" data-index-in-node=\"0\"\u003eFlexible Acceleration\/Deceleration Profiles:\u003c\/b\u003e Offers 10 selectable acceleration and deceleration ramps to prevent sample resuspension and protect sensitive gradients.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,6,0\"\u003e\n\u003cb data-path-to-node=\"0,6,0\" data-index-in-node=\"0\"\u003eWide Programmable Timer:\u003c\/b\u003e Integrated timer adjustable from 0 to 99 minutes and 59 seconds, with a continuous run mode option for extended runs.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,7,0\"\u003e\n\u003cb data-path-to-node=\"0,7,0\" data-index-in-node=\"0\"\u003eCustom Protocol Storage:\u003c\/b\u003e Integrated program memory allows saving, storing, and quickly recalling multiple custom protocol parameters for repeatable testing conditions.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,8,0\"\u003e\n\u003cb data-path-to-node=\"0,8,0\" data-index-in-node=\"0\"\u003eDurable Construction:\u003c\/b\u003e Built with a heavy-gauge steel outer chassis and a corrosion-resistant, high-grade stainless steel centrifugal chamber for easy decontamination.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,9,0\"\u003e\n\u003cb data-path-to-node=\"0,9,0\" data-index-in-node=\"0\"\u003eElectronic Lid Safety Lock System:\u003c\/b\u003e Features an automatic motorized door lock mechanism that prevents the lid from opening while the rotor is in motion and inhibits operation if the lid is unlocked.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,10,0\"\u003e\n\u003cb data-path-to-node=\"0,10,0\" data-index-in-node=\"0\"\u003eDynamic Imbalance Detection:\u003c\/b\u003e Internal imbalance sensor continuously monitors rotor stability and automatically cuts power if off-balance tube loading is detected.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,11,0\"\u003e\n\u003cb data-path-to-node=\"0,11,0\" data-index-in-node=\"0\"\u003eComprehensive Safety Safeguards:\u003c\/b\u003e Outfitted with automatic over-speed protection, motor over-temperature monitoring, and self-diagnostic fault indicators.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,12,0\"\u003e\n\u003cb data-path-to-node=\"0,12,0\" data-index-in-node=\"0\"\u003eAcoustically Dampened Operation:\u003c\/b\u003e Optimized airflow and motor dampening deliver ultra-quiet performance (\u0026lt;62 dBA) to maintain a peaceful workspace.\u003c\/li\u003e\n\u003cli data-path-to-node=\"0,13,0\"\u003e\n\u003cb data-path-to-node=\"0,13,0\" data-index-in-node=\"0\"\u003eEmergency Lid Release:\u003c\/b\u003e Manual emergency release mechanism allows safe recovery of samples in the event of a power outage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,1,0,0\"\u003e\u003cb data-path-to-node=\"1,1,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,1,1,0\"\u003eUSA-UG20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,2,0,0\"\u003e\u003cb data-path-to-node=\"1,2,0,0\" data-index-in-node=\"0\"\u003eProduct Name\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,2,1,0\"\u003eUSA-UG20 Table Top High Speed Centrifuge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,3,0,0\"\u003e\u003cb data-path-to-node=\"1,3,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,3,1,0\"\u003eUSA Lab\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,4,0,0\"\u003e\u003cb data-path-to-node=\"1,4,0,0\" data-index-in-node=\"0\"\u003eEquipment Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,4,1,0\"\u003eTable Top High Speed Centrifuge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,5,0,0\"\u003e\u003cb data-path-to-node=\"1,5,0,0\" data-index-in-node=\"0\"\u003eControl \/ Working Mode\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,5,1,0\"\u003eMicroprocessor Control with Digital LCD Display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,6,0,0\"\u003e\u003cb data-path-to-node=\"1,6,0,0\" data-index-in-node=\"0\"\u003eMax. Speed\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,6,1,0\"\u003e21,000 r\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,7,0,0\"\u003e\u003cb data-path-to-node=\"1,7,0,0\" data-index-in-node=\"0\"\u003eMax. RCF\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,7,1,0\"\u003e30,910 × g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,8,0,0\"\u003e\u003cb data-path-to-node=\"1,8,0,0\" data-index-in-node=\"0\"\u003eMax. Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,8,1,0\"\u003e6 × 100 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,9,0,0\"\u003e\u003cb data-path-to-node=\"1,9,0,0\" data-index-in-node=\"0\"\u003eRotor Capacity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,9,1,0\"\u003e6 × 100 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,10,0,0\"\u003e\u003cb data-path-to-node=\"1,10,0,0\" data-index-in-node=\"0\"\u003eRotor Connection\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,10,1,0\"\u003eSpecialized taper sleeve connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,11,0,0\"\u003e\u003cb data-path-to-node=\"1,11,0,0\" data-index-in-node=\"0\"\u003eTimer\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,11,1,0\"\u003e0–99 h 59 min 59 sec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,12,0,0\"\u003e\u003cb data-path-to-node=\"1,12,0,0\" data-index-in-node=\"0\"\u003eSpeed Accuracy\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,12,1,0\"\u003e±20 r\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,13,0,0\"\u003e\u003cb data-path-to-node=\"1,13,0,0\" data-index-in-node=\"0\"\u003eNoise Level\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,13,1,0\"\u003e≤62 dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,14,0,0\"\u003e\u003cb data-path-to-node=\"1,14,0,0\" data-index-in-node=\"0\"\u003eProgrammable Settings\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,14,1,0\"\u003e9 settings; 10 acceleration\/deceleration profiles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,15,0,0\"\u003e\u003cb data-path-to-node=\"1,15,0,0\" data-index-in-node=\"0\"\u003eDimensions (L × W × H)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,15,1,0\"\u003e513 × 370 × 320 mm (20 × 14.5 × 12.6 in.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,16,0,0\"\u003e\u003cb data-path-to-node=\"1,16,0,0\" data-index-in-node=\"0\"\u003eNet Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,16,1,0\"\u003e42 kg (93 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,17,0,0\"\u003e\u003cb data-path-to-node=\"1,17,0,0\" data-index-in-node=\"0\"\u003eElectrical Requirements\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,17,1,0\"\u003eAC 110V, 60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,18,0,0\"\u003e\u003cb data-path-to-node=\"1,18,0,0\" data-index-in-node=\"0\"\u003ePower\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,18,1,0\"\u003e300W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,19,0,0\"\u003e\u003cb data-path-to-node=\"1,19,0,0\" data-index-in-node=\"0\"\u003eSafety Features\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"1,19,1,0\"\u003eAutomatic electric lid lock, overspeed protection, overtemperature protection, imbalance detection, three-tier safety protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"USA Lab","offers":[{"title":"Centrifuge Only","offer_id":54910622957906,"sku":"USA-UG20","price":1910.0,"currency_code":"USD","in_stock":true},{"title":"24×1.5\/2ml Rotor","offer_id":54910622990674,"sku":"USA-UG20-KIT-24×1.5\/2ml","price":2790.0,"currency_code":"USD","in_stock":true},{"title":"6×50ml Rotor","offer_id":54910623023442,"sku":"USA-UG20-KIT-6×50ml","price":3350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0936\/5651\/4898\/files\/USA_Lab_Table_Top_High_Speed_Centrifuge_21000rpm_Multiple_Rotor_Options_110V_Precision_Control.webp?v=1790845219","url":"https:\/\/medidepot.com\/products\/usa-lab-usa-ug20-high-speed-centrifuge","provider":"MediDepot","version":"1.0","type":"link"}