Jeio Tech AAHK4058K PMV-100 Heating & Cooling Chamber 380V, 50/60Hz, 3P
Jeio Tech AAHK4058K PMV-100 Heating & Cooling Chamber 380V, 50/60Hz, 3P
Features
Performance
- Suitable for specific use such as heat treatment and drying process.
- Microprocessor PID control / Temperature calibration / Automatic tuning.
- Heat-resistant silicone packing completely blocks high heat leakage from the inner chamber.
- Two-point door latch also enhances tightness to door closure.
- Energy efficiency is achieved thanks to optimization of the insulation system.
- Even if the unit is operating at max. temperature, the surface of the unit doesn’t allow high temperatures of over 51℃. (DIN EN 563) - Reliable design and production of door is guaranteed.
- Evaluates the results after opening the door by 90 degrees and applying 50kg load to the point of 30cm from hinges.
Safety
- User selectable operation mode after power interruption
- ether Automatic run or Manual run. - Over-temperature protection.
- Over-current and current leakage protection. (ELCB, earth leakage circuit breaker)
- Independent safety fuse.
- Important parts such as controller and heaters are highly secured from short circuit. Especially each heater has an individual fuse to completely break a short circuit. - Reversed-phase protection.
- Electrical connection error indicator helps user to rapidly fix the connection. - Over-current protection of motor.
- Automatic shut-off in situations where there is over-current to the motor. - Open door warning.
- Heater and fan stop when the door is the open state. - Electric wiring panel access warning.
- Automatic stop if the cover of electric wiring panel is opened. - Built in door lock with a key.
Convenience
- Corrosion resistance stainless steel inner chamber.
- Space efficient and easy loading chamber design.
- Included two shelves for loading of large amounts of samples.
- Heavy load shelving, rated for 40kg are also available. (optional) - User friendly LCD controller.
- Colorful interactive touch type LCD controller.
- Set point temperature and present temperature are clearly shown together on display.
- Sufficient programmable control support.
- Operating progress can be shown in graph mode for better data understanding.
- Automatic start/stop can be programmed for unattended operations.
- Display indicates abnormal temperature changes or power failures.
- Three different language support. (English / Chinese / Korean)
- Temperature and other operating parameters can be recorded using a six channel digital recorder. (optional) - Computer interface.
- RS-485 communication port (optional) enables connection up to maximum 32 units. Simultaneous monitoring and operating of multiple units is an available feature.
- Program patterns are simple to set with the use of our software.
- Easy to check status of real-time operations. Graph data supports easy understanding.
- Storage and documentation of programs.
- Data with saving capabilities in excel and text format.
- Storage of program information, backup of value settings, recovery, and temperature values.
- RS-232 communication port as standard offer
Specifications
| Model | PMV-012 | PMV-025 | PMV-040 | PMV-070 | PMV-100 |
| Temperature data | |||||
| Range (℃ / ℉) | -5 to 100 / 23 to 212 | -5 to 100 / 23 to 212 | -5 to 100 / 23 to 212 | -5 to 100 / 23 to 212 | -5 to 100 / 23 to 212 |
| Fluctuation (±℃ / ±℉) 1), 2) | |||||
| at -5℃ | 0.3 / 0.54 | 0.3 / 0.54 | 0.2 / 0.36 | 0.2 / 0.36 | 0.3 / 0.54 |
| at 0℃ | 0.3 / 0.54 | 0.3 / 0.54 | 0.2 / 0.36 | 0.2 / 0.36 | 0.3 / 0.54 |
| at 25℃ | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 |
| at 40℃ | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 |
| at 60℃ | 0.3 / 0.54 | 0.3 / 0.54 | 0.2 / 0.36 | 0.2 / 0.36 | 0.3 / 0.54 |
| at 80℃ | 0.3 / 0.54 | 0.2 / 0.36 | 0.2 / 0.36 | 0.3 / 0.54 | 0.2 / 0.36 |
| at 100℃ | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 | 0.4 / 0.72 | 0.3 / 0.54 |
| Gradient (±℃ / ±℉)1) | |||||
| at -5℃ | 0.4 / 0.72 | 0.4 / 0.72 | 0.4 / 0.72 | 0.4 / 0.72 | 0.3 / 0.54 |
| at 0℃ | 0.4 / 0.72 | 0.4 / 0.72 | 0.4 / 0.72 | 0.4 / 0.72 | 0.3 / 0.54 |
| at 25℃ | 0.2 / 0.36 | 0.2 / 0.36 | 0.3 / 0.54 | 0.4 / 0.72 | 0.3 / 0.54 |
| at 40℃ | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 | 0.4 / 0.72 | 0.3 / 0.54 |
| at 60℃ | 0.5 / 0.9 | 0.5 / 0.9 | 0.4 / 0.72 | 0.4 / 0.72 | 0.4 / 0.72 |
| at 80℃ | 0.7 / 1.26 | 0.7 / 1.26 | 0.6 / 1.08 | 0.5 / 0.9 | 0.5 / 0.9 |
| at 100℃ | 1.01.2008 | 1.01.2008 | 0.8 / 1.44 | 0.7 / 1.26 | 0.7 / 1.26 |
| Heating time (min)2) | |||||
| from -5℃ to 25℃ | 24 | 24 | 21 | 17 | 19 |
| from 0℃ to 25℃ | 20 | 20 | 17 | 15 | 16 |
| from 25℃ to 40℃ | 16 | 16 | 15 | 11 | 11 |
| from 25℃ to 60℃ | 30 | 30 | 26 | 23 | 25 |
| from 25℃ to 80℃ | 32 | 32 | 33 | 34 | 38 |
| from 25℃ to 100℃ | 45 | 45 | 48 | 52 | 56 |
| from -5℃ to 100℃ | 60 | 60 | 62 | 64 | 75 |
| Cooling time (min)2) | |||||
| from 25℃ to -5℃ | 36 | 36 | 35 | 31 | 31 |
| from 25℃ to 0℃ | 30 | 30 | 27 | 25 | 25 |
| from 40℃ to 25℃ | 17 | 17 | 16 | 14 | 16 |
| from 60℃ to 25℃ | 37 | 37 | 35 | 31 | 31 |
| from 80℃ to 25℃ | 52 | 37 | 48 | 43 | 45 |
| from 100℃ to 25℃ | 65 | 65 | 62 | 59 | 57 |
| from 100℃ to -5℃ | 97 | 97 | 92 | 87 | 91 |
| Recovery time after door was opened for 30sec. (min)2) | |||||
| at -5℃ | 8.0 | 8.0 | 6.5 | 5.0 | 5.0 |
| at 0℃ | 6.0 | 6.0 | 6.0 | 6.0 | 8.0 |
| at 25℃ | 0.5 | 0.5 | 4.0 | 6.0 | 6.0 |
| at 40℃ | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
| at 60℃ | 4.0 | 4.0 | 4.5 | 5.0 | 6.0 |
| at 80℃ | 5.0 | 5.0 | 5.0 | 5.5 | 6.0 |
| at 100℃ | 7.0 | 7.0 | 7.0 | 6.5 | 8.0 |
| Electrical requirement (230V, 60Hz, 1Ph) | 15.5 | 21.7 | |||
| Electrical requirement (380V, 50/60Hz, 3Ph) | 9.7 | 13.2 | |||
| Electrical requirement (380V, 50/60Hz, 3Ph) | 6 | ||||