So-Low HCN4-24 Humidity Stability Chamber & Incubator, 4°C to 70ºC, 23 cu.ft.
Fast & Reliable Shipping
Typically 1-3 Business Days
Regulatory Compliant
Registered & Certified Medical Equipment
Support
Need help?
Fast & Reliable Shipping
Typically 1-3 Business Days
Regulatory Compliant
Registered & Certified Medical Equipment
Support
Need help?
So-Low HCN4-24 Humidity Stability Chamber & Incubator, 4°C to 70ºC, 23 cu.ft., Digital Display
|
Manufacturer
|
So-Low |
|
Capacity [ Cubic Feet ]
|
23 Cubic Feet |
|
Capacity [ Liters ]
|
651 Liters |
|
Temperature Range [ °C ]
|
4°C to 70°C |
|
Temperature Range [ °C ]
|
39°F to 158°F |
|
Dimensions
|
[ W x D x H ] |
|
Exterior [ Inches ]
|
26.75" x 35.75" x 80.75" |
|
Interior [ Inches ]
|
22" x 25.5" x 59" |
|
Exterior [ Centimeters ]
|
68 x 90 x 203 |
|
Interior [ Centimeters ]
|
56 x 64 x 150 |
General Specifications:
| Air Circulation | Plenum System |
| Drain | Floor Drain |
| Compressor(s) | Hermetic Compressor |
| Refrigeration | R600a |
| Insulation | Polyurethane |
| Opening | 1 Front Door |
| Opening Type | Hinged |
| Door Material | Insulated Steel |
| Lockable Door | Keyed Lock |
| Access Porthole | 3/4" Diameter |
| Storage | 3 Adjustable Stainless Tray Shelves |
| Exterior | Powder Coated Steel |
| Interior | Stainless Steel |
| Interior Lighting | Adjustable LED |
| Casters | 4, Locking |
| Warranty | 18 Months Parts and Labor |
| 3 years on Compressor Parts (No Labor) |
Control Specifications:
| Temperature Control | Digital Display |
| Min / Max Temperature | Display and Reset |
| Temperature Alarm | Audible High / Low Alarm |
| Process Phase Specific | |
| Additional Alarm Types | Power Failure, Sensor Failure |
| Programmable | Ramp and Soak |
| Event Logger | Stores 100 Previous Events |
| Clock | Real Time Clock |
| Data Connections | RS-485 (MODBUS-RTU) |
| Data Download | Via, USB |
| Battery Backup | Only Powers Alarm |
| Alarm Relay | Dry Contacts |
| Humidity Set-point Range | 15% to 95% Relative Humidity |
| Humidity Control | ±0.1°% Relative Humidity |
| Humidity Stability | ±3.0% Relative Humidity (Range Dependent) |
| Temperature Adjustment | ±0.1°C |
| Temperature Stability | ±0.5°C From 4°C to 70°C (Range Dependent) |
| Temperature Uniformity | ±1.0°C From 4°C to 70°C (Range Dependent) |
Electrical Specifications:
| Voltages Available | 115 Volts 60 Hertz 1 Phase |
| Amperage | 15 Amp Dedicated Line |
| 12 Running Amps | |
| NEMA Configuration | NEMA 5-15 |
| Certification(s) | ETL Listed |