Jeio Tech AAH14XXXX, OF4-XXXX Standard Forced Convection Oven, Solid/Window Door, 26L to 147L, 120V/230V - 50/60Hz
Features
Standard type that provides the device information intuitively (OF4-S)
- 3.5-Inch touch controller that enables intuitive control of the device.
- Wait on/Wait off timer setting allowing efficient test schedule management.
Reliable temperature control performance based on stable control mechanisms
- Wide temperature range of up to 250℃.
- Three-point temperature calibration that ensures hightemperature accuracy over a wide temperature range.
- Available to set the upper and lower temperature limit, alarm activated to quick response when occurring the deviation.
- Excellent temperature distribution through the formation of optimal airflow for uniform heat transfer.
(±1.9℃ or below at 100℃)
Convenient checking for the test progress and data
- RS-232/USB port and compatible software provided to enable easy device control and data management using PC. (option)
- Monitor and control via mobile app anytime, anywhere with LC Connected. (mobile monitoring system) (option)
- BMS communication port that helps monitor the device temperature on the building management system. (option)
- Integrated with 21 CFR Part 11 compliant LC DataKeeper, suitable for GMP audits (option)
Various safety features for improved user safety
- The upper vent hole releases effectively fume inside the oven when using local ventilation equipment. (OF4-03)
- Device surface not overheating even in operation at the highest temperature. (70℃ or below, at 250℃)
- Top-rated overheating protection system. (registration KR 10-0397583)
- Over temperature limit function.
- Equivalent to IEC protection Class II.
Structural and functional features for improved user convenience
- Recording the 12 most recent events, such as start/stop of operation, the operating time, and error occurrence.
- Stacking Kit (option) ensuring the safe fitting of one unit to another, thus doubling the amount of work done in a given area for improved space efficiency.
- Hands-free™ door system to allow users to easily open the door while carrying samples with both hands.
- (±1.9℃ or below at 100℃)
Specifications
| Model | Solid door (without window) | OF4-03S | OF4-05S | OF4-10S | OF4-15S | |||
|---|---|---|---|---|---|---|---|---|
| Window door | OF4-03SW | OF4-05SW | OF4-10SW | OF4-15SW | ||||
| Chamber volume (L/cu ft) | 26/0.92 | 61/2.15 | 112/3.96 | 147/5.19 | ||||
| Temperature 1) | Range (℃/℉) | Amb. + 10~250 / Amb. + 18 ~ 482 | ||||||
| Fluctuation at 100℃ (±℃/±℉) | 0.3/0.54 | 0.3/0.54 | 0.3/0.54 | 0.3/0.54 | ||||
| Variation at 100℃ (±℃/±℉) | 1.4/2.52 | 1.9/3.42 | 1.7/3.06 | 1.5/2.70 | ||||
| Heating time to 100℃ (min) | 8 | 10 | 14 | 15 | ||||
| Recovery time at 100℃ (min) | 4 | 4 | 4 | 4 | ||||
| Control Panel | 3.5inch TFT Color LCD | |||||||
| Communication interface | USB, RS-232 (Option) | |||||||
| Function | Recently event record | 12ea | ||||||
| Dimensions | Interior (W x D x H, mm/inch) | 300 x 210 x 400 / 11.80 x 8.27 x 15.75 |
380 x 330 x 480 / 14.97 x 13.0 0x 18.90 |
485 x 350 x 655 / 19.09 x 13.78 x 25.79 |
550 x 376 x 710 / 21.65 x 14.80 x 27.95 |
|||
| Exterior (W x D x H, mm/inch) | 478 x 527 x 604 / 18.82 X 20.75 X 23.78 |
558 x 648 x 684 / 21.97 X 25.51 X 26.93 |
663 x 677 x 859 / 26.1 X 26.65 X 33.82 |
728 x 704 x 914 / 28.66 X 27.72 X 35.98 |
||||
| Net weight (kg/lbs) | 33/72.8 | 53/116.8 | 63/138.9 | 73/160.9 | ||||
| Shelves | Quantity of shelves (Standard/max.) |
2/4 | 2/5 | 2/8 | 2/9 | |||
| Max. Load per shelf (kg/lbs) | 30/66.1 | |||||||
| Number of Air change per hour at 100 ℃ 2) | 123 | 22 | 18 | 11 | ||||
| Electrical requirements (230V, 50/60Hz, A) | 6.4 | |||||||
| Cat. No. | Solid door (without window) | AAH14115K | AAH14125K | AAH14135K | AAH14145K | |||
| Window door | AAH14215K | AAH14225K | AAH14235K | AAH14245K | ||||
| Electrical requirements (120V, 60Hz, A) | 12.3 | |||||||
| Cat. No. | Solid door (without window) | AAH14116U | AAH14126U | AAH14136U | AAH14146U | |||
| Window door | AAH14216U | AAH14226U | AAH14236U | AAH14246U | ||||
Standard delivery typically takes 5-7 business days, while expedited shipping takes 2-3 business days
Request a Quote
Build your list and our team will reply with a line-item quote within 4 business hours.
1
Your quote list 0
Your list is empty. Add the product above or use the search below to get started.
Anything else you’d like to add?
You may also need
Request received!
Thank you! Our team will review your request and reply with a detailed, line-item quote within 4 business hours.