Features
Standard type that provides the device information intuitively (OF4-S)
- 3.5-Inch touch controller that enables intuitive control of the device.
- Wait on/Wait off timer setting allowing efficient test schedule management.
Reliable temperature control performance based on stable control mechanisms
- Wide temperature range of up to 250℃.
- Three-point temperature calibration that ensures hightemperature accuracy over a wide temperature range.
- Available to set the upper and lower temperature limit, alarm activated to quick response when occurring the deviation.
- Excellent temperature distribution through the formation of optimal airflow for uniform heat transfer.
(±1.9℃ or below at 100℃)
Convenient checking for the test progress and data
- RS-232/USB port and compatible software provided to enable easy device control and data management using PC. (option)
- Monitor and control via mobile app anytime, anywhere with LC Connected. (mobile monitoring system) (option)
- BMS communication port that helps monitor the device temperature on the building management system. (option)
- Integrated with 21 CFR Part 11 compliant LC DataKeeper, suitable for GMP audits (option)
Various safety features for improved user safety
- The upper vent hole releases effectively fume inside the oven when using local ventilation equipment. (OF4-03)
- Device surface not overheating even in operation at the highest temperature. (70℃ or below, at 250℃)
- Top-rated overheating protection system. (registration KR 10-0397583)
- Over temperature limit function.
- Equivalent to IEC protection Class II.
Structural and functional features for improved user convenience
- Recording the 12 most recent events, such as start/stop of operation, the operating time, and error occurrence.
- Stacking Kit (option) ensuring the safe fitting of one unit to another, thus doubling the amount of work done in a given area for improved space efficiency.
- Hands-free™ door system to allow users to easily open the door while carrying samples with both hands.
- (±1.9℃ or below at 100℃)
Specifications
| Model | Solid door (without window) | OF4-03S | OF4-05S | OF4-10S | OF4-15S | |||
|---|---|---|---|---|---|---|---|---|
| Window door | OF4-03SW | OF4-05SW | OF4-10SW | OF4-15SW | ||||
| Chamber volume (L/cu ft) | 26/0.92 | 61/2.15 | 112/3.96 | 147/5.19 | ||||
| Temperature 1) | Range (℃/℉) | Amb. + 10~250 / Amb. + 18 ~ 482 | ||||||
| Fluctuation at 100℃ (±℃/±℉) | 0.3/0.54 | 0.3/0.54 | 0.3/0.54 | 0.3/0.54 | ||||
| Variation at 100℃ (±℃/±℉) | 1.4/2.52 | 1.9/3.42 | 1.7/3.06 | 1.5/2.70 | ||||
| Heating time to 100℃ (min) | 8 | 10 | 14 | 15 | ||||
| Recovery time at 100℃ (min) | 4 | 4 | 4 | 4 | ||||
| Control Panel | 3.5inch TFT Color LCD | |||||||
| Communication interface | USB, RS-232 (Option) | |||||||
| Function | Recently event record | 12ea | ||||||
| Dimensions | Interior (W x D x H, mm/inch) | 300 x 210 x 400 / 11.80 x 8.27 x 15.75 |
380 x 330 x 480 / 14.97 x 13.0 0x 18.90 |
485 x 350 x 655 / 19.09 x 13.78 x 25.79 |
550 x 376 x 710 / 21.65 x 14.80 x 27.95 |
|||
| Exterior (W x D x H, mm/inch) | 478 x 527 x 604 / 18.82 X 20.75 X 23.78 |
558 x 648 x 684 / 21.97 X 25.51 X 26.93 |
663 x 677 x 859 / 26.1 X 26.65 X 33.82 |
728 x 704 x 914 / 28.66 X 27.72 X 35.98 |
||||
| Net weight (kg/lbs) | 33/72.8 | 53/116.8 | 63/138.9 | 73/160.9 | ||||
| Shelves | Quantity of shelves (Standard/max.) |
2/4 | 2/5 | 2/8 | 2/9 | |||
| Max. Load per shelf (kg/lbs) | 30/66.1 | |||||||
| Number of Air change per hour at 100 ℃ 2) | 123 | 22 | 18 | 11 | ||||
| Electrical requirements (230V, 50/60Hz, A) | 6.4 | |||||||
| Cat. No. | Solid door (without window) | AAH14115K | AAH14125K | AAH14135K | AAH14145K | |||
| Window door | AAH14215K | AAH14225K | AAH14235K | AAH14245K | ||||
| Electrical requirements (120V, 60Hz, A) | 12.3 | |||||||
| Cat. No. | Solid door (without window) | AAH14116U | AAH14126U | AAH14136U | AAH14146U | |||
| Window door | AAH14216U | AAH14226U | AAH14236U | AAH14246U | ||||