10% off
10% off
10% off
Jeio Tech AAH860332K TC3-ME-100 Low Temperature Chamber(100L) 230V, 50/60Hz
Jeio Tech AAH860332K TC3-ME-100 Low Temperature Chamber(100L) 230V, 50/60Hz
Features
Optimized Model Configuration
- 2 series (KE, ME) according to temperature control range.
TC3-KE ; -40 ~ 100℃
TC3-ME ; -20 ~ 100℃ - Standard type Temp. & Humid chamber for selecting the optimized model according to test conditions.
- Dedicated stand for convenient use and moving.(option)
- Recorder for maintaining test records. (option)
Structural functional features
- Proven reproducibility and reliability with structural design optimized for miniaturization.
- Compact design for excellent space saving.
- Excellent thermal insulation and sealing to ensure stable temperature and humidity reproducibility even for repeated test use.
- The door part has a double sealing structure and excellent airtightness.
Use Convenience Features
- Convenient operation with 5.6 inch color touch display controller.
- Easy observation of samples with tempered glass door with built in heating wire and LED lamp.
- By displaying the operation status of the device with LED colors, convenient to identify chambers status from a far.
- The cable port(ø 50 mm) included as standard make it convenient to connect external equipment.
- The door structure can be easily opened or closed.
- Door handle with built-in key lock.
- Identification of the control and operating conditions at the front of the product.
- Design by stainless steel internal chamber made of stainless steel provide clean maintenance and excellent corrosion resistance.
- Easy to clean as it is easy to remove refrigerator condenser grill, making it convenient to maintain efficiency of refrigeration.
- Equipped with easy-to-move/install caster.
- Monitor via mobile app anytime, anywhere with LC Connected. (Requires LC GreenBox, option)
- Integrated with 21 CFR Part 11 compliant LC DataKeeper, suitable for GMP audits (option)
Multifunction Control System
- Highly-reliable control through calibration.
- Auto-tuning by subdivided PID zone for more precise control stability.
- RS-232 port (default) and RS-485 port (option) supported.
- Control and data v processing by connecting up to 32 devices to PC at same time via RS-485 port.
- Convenient checking with useful graph display.
Outstanding Safety
- Electronic over temperature protection system.(A-OT, advanced over temperature limiter)
Independent precision temperature sensor and controller for safer and more accurate over temperature shutdown. - Conventional over-temperature protection.(B-OT, backup over temperature limiter)
A backup device for electronic system failure, mechanically preventing over temperature even when it occurs electronic errors. - Door open warning and automatic shut off.
- Over-current and short circuit protection of device.
- Each heater has fuse for more being safe use.
- Automatic stop when operating current of refrigerator is overloaded.
- Automatic stop in case of over temperature of the compressor.
- Auto shut off in case refrigerant pressure (high/low pressure) is abnormal.
Specifications
| Model | TC3-ME-025 | TC3-ME-065 | TC3-ME-100 | |
| Temperature data | ||||
| Range (℃ / ℉) | -20 to 100 | -20 to 100 | -20 to 100 | |
| / -4 to 212 | / -4 to 212 | / -4 to 212 | ||
| Fluctuation (±℃ / ℉) 1) | 0.3 / 0.54 | 0.3 / 0.54 | 0.3 / 0.54 | |
| Variation (±℃ / ℉) 2) | 0.5 / 0.9 | 0.5 / 0.9 | 0.5 / 0.9 | |
| Heating time 3) | 50 | 50 | 50 | |
| Cooling time 4) | 55 | 55 | 55 | |
| Interior dimensions | ||||
| Chamber volume (L / cu ft) | 25 / 0.88 | 65 / 2.3 | 100 / 3.53 | |
| Width (mm / inch) | 350 / 13.8 | 400 / 15.7 | 500 / 19.7 | |
| Depth (mm / inch) | 220 / 8.7 | 330 / 13 | 380 / 15 | |
| Height (mm / inch) | 350 / 13.8 | 495 / 19.5 | 530 / 20.9 | |
| Quantity of shelves (standard/max.) | 2.7 | 2.10 | 2.10 | |
| Distance of between shelves (mm / inch) | 20 / 0.8 | 20 / 0.8 | 20 / 0.8 | |
| Max. load per shelf (kg /lbs) | 25 / 55.1 | 25 / 55.1 | 25 / 55.1 | |
| Permitted total load (kg / lbs) | 65 / 143.3 | 65 / 143.3 | 65 / 143.3 | |
| Cable port (Ø, mm / inch) | 50 / 2 | 50 / 2 | 50 / 2 | |
| Weight (kg / lbs) | 80 / 176.4 | 110 / 242.5 | 130 / 286.6 | |
| Electrical requirements (AC230V, 1ph, 50/60Hz) | Cat. No. | 5.5A | 6.5A | 8.6A |