Short answer: read the model code. Plus means digital display and alarms, a -TS ending means touchscreen with data logging (Performance), PLD or SPLD means Premium with a variable speed compressor, and FRP or ERP means the unit is built for flammable or hazardous location storage. Pick the series by how much monitoring you need, then the door and size.
Who this guide is for
Lab managers, research coordinators and purchasing teams comparing VWR refrigerators for reagents, samples, media and chemicals. If you are still deciding between brands or refrigerator types, start with our lab refrigerator pillar guide and come back here for the VWR lineup.
What this guide covers
How to decode a VWR model number, what separates the Standard, Plus, Performance and Premium series, glass versus solid doors, fridge and freezer combos, flammable storage versus explosion proof models, a comparison table of eight current units and a selection checklist.
Quick start
1) Write down what you store and whether any of it is flammable. 2) Decide if you need on-board data logging for audits. 3) Measure the space and pick glass or solid door. The comparison table below then narrows 203 VWR products to a shortlist of two or three.
One model code tells you most of it
Every VWR refrigeration code starts with VWR-HC, and the letters after it are the specification in shorthand. An S before the size means solid door (HC-26S), TS at the end means touchscreen, PLD and SPLD are the Premium glass and solid door lines, RFC is a refrigerator and freezer combo, FRP is flammable material storage, and ERP, ERS or ERFC are hazardous location units. The number is the capacity in cubic feet, from 5 cu ft undercounters to 72 cu ft double door uprights.
That shorthand matters when you order, because two units that look identical in a photo can sit $2,000 apart in capability. The sections below walk the real decisions in order.
Plus, Performance or Premium: what actually changes?
The series decides the controller, not the cold. All four series hold the laboratory band of roughly 2°C to 10°C; what you pay for is how the unit documents and defends that temperature. Plus gives you a digital display with high and low alarms. Performance adds a touchscreen and on-board data logging, which auditors like because the record builds itself. Premium keeps the touchscreen and adds a variable speed compressor running on natural refrigerant (R600a or R290), so the unit trims output to the load instead of cycling hard on and off. The US EPA's SNAP program lists these hydrocarbon refrigerants as acceptable alternatives to older HFCs.
| Series | Code clue | Controller | Best for | Entry price |
|---|---|---|---|---|
| Standard | SLS, HCLS, RFP, ERP | Digital or dial, swing door | Budget buys, backup units | From $5,095 |
| Plus | HC-## and RFC, FRP-##P | Digital display + alarm module | Most everyday lab storage | From $2,869 |
| Performance | code ends in -TS | Touchscreen + data logging | Logged, audited storage | From $9,330 |
| Premium | PLD / SPLD + TS | Touchscreen + variable speed compressor | Tight stability, low noise | From $10,283 |
Here is the cleanest series comparison in the lineup: the same 26 cu ft glass door box as a Plus and as a Performance. The $1,920 difference is the touchscreen and the data logging.
Glass door or solid door?
Glass doors let staff find samples without opening the door, which protects the temperature more than any compressor upgrade. Solid doors insulate better, matter for light-sensitive media, and keep curious eyes off controlled materials. VWR prices the choice neutrally: the Premium 23 cu ft glass and solid door models below cost exactly the same, so choose by what you store, not by budget.
Need fridge and freezer in one footprint?
RFC combo units stack a separate refrigerator and freezer compartment, each with its own door, in a single upright footprint. Small clinics and satellite labs use them where floor space is the scarce resource. The 9 cu ft RFC9G is the budget entry to the whole VWR lineup; the RFC12 adds capacity and a solid door. If your frozen storage is the harder problem, size that side first with our lab freezer size comparison.
Flammable storage or explosion proof?
The difference is where the vapors are. A flammable storage model (FRP) keeps every spark source out of the storage compartment, so flammable liquids can sit inside it in an ordinary lab room. A hazardous location model (ERP, ERS, ERFC) is built for rooms that are themselves classified, such as Class I Division 2: the entire unit avoids ignition sources and is usually hardwired. OSHA's flammable liquids standard, 29 CFR 1910.106, governs this storage, and your fire marshal or safety officer makes the classification call. Our flammable storage versus explosion proof guide walks the decision in detail.
Mistakes That Repeat
- Buying Standard for audited storage. The unit holds temperature, but every audit then needs a separate logger and a manual records routine, which costs more attention than the -TS upgrade would have.
- Choosing glass for light-sensitive media. Some reagents and media degrade under light, and a lit glass door display works against you. Check the labels before you pick the showroom look.
- Putting flammables in a general purpose unit. An ordinary interior has a light, a fan and a thermostat, and each one is an ignition source. This is the single most dangerous shortcut in lab refrigeration.
- Paying for explosion proof when flammable storage was the need. If the room is unclassified, the FRP line does the job; the hazardous location premium buys protection your room does not require.
- Sizing to today's inventory. A refrigerator packed wall to wall cannot circulate air, so temperatures drift shelf to shelf. Leave a third of the volume free and plan for next year's samples, not last year's.
Comparison Table
| Model | Series | Door | Capacity | Defining feature |
|---|---|---|---|---|
| VWR-HC-26 | Plus | Glass | 26 cu ft | Digital display, alarms |
| VWR-HC-26-TS | Performance | Glass | 26 cu ft | Touchscreen, data logging |
| VWR-HC-PLD-23-TS | Premium | Glass | 23 cu ft | Variable speed, R600a |
| VWR-HC-SPLD-23-TS | Premium | Solid | 23 cu ft | Variable speed, R600a |
| VWR-HC-RFC9G | Plus | Glass | 9 cu ft | Fridge + freezer combo |
| VWR-HC-RFC12 | Plus | Solid | 12 cu ft | Fridge + freezer combo |
| VWR-HC-FRP-14P | Plus | Solid | 14 cu ft | Flammable storage interior |
| VWR-HC-ERP-14 | Standard | Solid | 14 cu ft | Class I Div 2 rated unit |
Confirm size, electrical requirements and exact specifications by model and variant before ordering. Prices shown in the product cards are starting prices checked on November 18, 2026 and can change.
✅ Selection Checklist
- ☐ Anything flammable going inside? If yes, FRP at minimum; classified room means ERP/ERS/ERFC.
- ☐ Do audits require temperature records? If yes, choose a -TS model or budget a separate logger.
- ☐ Glass door for visibility, or solid door for insulation and light protection?
- ☐ Capacity with a third of the space left free for airflow, plus growth.
- ☐ Door swing, aisle clearance and 120V circuit (hazardous location models: hardwiring by an electrician).
- ☐ Alarm outputs or monitoring hookup, covered in our temperature monitoring guide.
Ordering & Smart Solutions
Every VWR refrigerator at MediDepot ships with our standard support: equipment financing, a price match policy, extended warranty options and a military discount. For multi-unit lab fit-outs, request a quote and we will spec the lineup against your floor plan.
Explore Related MediDepot Guides
- Lab Refrigerators: What You Store Decides Which One You Need
- Flammable Storage vs Explosion-Proof Refrigerators
- Medical Refrigerator Temperature Monitoring Guide
- Laboratory Freezer Size Comparison Guide
- Lab Ovens and Incubators: Which One Does Your Protocol Need
- Medical Refrigeration: The Complete Buying Hub
Browse the equipment: VWR part of Avantor · Laboratory Refrigerators · Flammable Storage · All Lab Refrigeration & Freezers
Frequently Asked Questions
Q1: What is the difference between VWR Plus, Performance and Premium series?
Plus models use a digital display with alarms. Performance models (TS in the code) add a touchscreen controller and data logging. Premium models (PLD or SPLD) add a variable speed compressor on top of the touchscreen, which smooths temperature swings and cuts noise. Standard series models are the entry point, with swing doors and simpler controls.
Q2: What does TS mean in a VWR refrigerator model number?
TS stands for touchscreen. Any VWR code ending in -TS has the touchscreen controller with on-board data logging, for example VWR-HC-26-TS or VWR-HC-SPLD-49-TS.
Q3: Can I store flammable chemicals in a regular VWR lab refrigerator?
No. Flammable liquids belong in an FRP flammable storage model, which keeps ignition sources out of the storage compartment. OSHA regulates flammable liquid storage under 29 CFR 1910.106, and your safety officer decides which rating your room requires.
Q4: What is the difference between VWR FRP and ERP models?
FRP is flammable material storage: the inside of the cabinet is spark free, and the unit sits in an ordinary lab. ERP, ERS and ERFC are hazardous location models for classified areas such as Class I Division 2: the whole unit, inside and out, is built to avoid ignition, and it is typically hardwired by an electrician.
Q5: What temperature range do VWR lab refrigerators hold?
Most VWR laboratory refrigerators operate in the 2°C to 10°C band, with many models set around 4°C. Combo units add a separate freezer compartment. Always match the setpoint to the labels of what you store.
Q6: Who makes VWR lab refrigerators?
VWR has been part of Avantor since 2019. VWR branded refrigeration is sold through laboratory distribution, and MediDepot carries the current lineup from compact combos to 72 cu ft uprights.
Still comparing? Browse the full VWR part of Avantor collection at MediDepot.
Ready to Choose Your VWR Refrigerator?
From a 9 cu ft fridge and freezer combo to a 72 cu ft touchscreen upright, request a quote and we'll match the series, door and size to your lab.
Published: November 18, 2026 · Last updated: November 18, 2026
This guide covers equipment selection, not laboratory safety procedure. Storage classification and placement decisions belong to your safety officer and local fire code. Sources: OSHA 29 CFR 1910.106, US EPA SNAP program, Avantor, manufacturer specification sheets.